Meter Link
Brand Name: Clipsal
Type: Active
Mini
Range: Blue Point Series
Conductor Size: 16 sq-mm
Voltage: 500 V
Length: 57 mm x 30 mm x 26 mm
Material: Brass
Color: Red
Connection Type: Screw
Current: 100 A
Number of Tunnels: 7
Mounting Center: 46 mm
Clipsal Link Active 7 Hole - L7R
This item is currently available for backorder with an estimated arrival time of 2 days
Please note this ETA is provided to us by our suppliers and could potentially be delayed due to factors outside our control. If there are any delays we will contact you to keep you updated.
Choose your style, Select your Switch and Checkout
We can customise your powerpoint to a range of colours and layouts, suited to your needs.
Clipsal Link Active 7 Hole - L7R
SKU | CLIL7R |
---|---|
Supplier No | L7R |
EAN / Barcode | 9318793006736 |
Width | 50 |
Height | 52.000000 |
Length | 65.000000 |
Width | 46.000000 |
Brand | Clipsal |
Range | Max4 |
Voltage | 500 V |
Material | Brass |
Get Max 4 your buck
Complete protection with high performance. With Clipsal Max 4 you will find a range of enclosures, switchboards, residual current devices, miniature circuit breakers, isolators, distribution boards, overvoltage protection and accessories.
A FEW FAQS
Issue: Can't find LFr parameter to control in keypad mode and has Altivar ATV16 with keypad VW3A16102. Product Line: ATV16 Environment: All Cause: No LFR parameter Resolution: The LFr parameter does not appear if the keypad part number VW3A16102 (which is required) datecode is before 9422.
The maximum DC voltage for TeSys F range contactors is 125 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.
The maximum DC voltage for TeSys D range contactor is 75 Volt per pole. This voltage is applicable for the specification of L/R <= 15ms in DC applications.
When reading the value of LCR parameter using Modbus the scaling unit varies as follows: 0,01 for all sizes below or equal to 15KW 0,1A between 18,5 to 160KW 1A over 160KW
Issue: Altivar 28 start/stop/speed controlled via remote keypad. Product Line: Altivar 28 Environment: All Cause: N/A Resolution: Go to the I/O ( input / output ) menu and set LCC ( local control) to Yes which no allows acces to LFR ( local frequency) parameter for local speed adjustment. To change the reference setting you will need to go to the SET menu and change parameter LFR each time desire to change the speed the drive is commanded to run at..
Issue: ATS48 tripping on ULF or motor underload fault. Product Line: Altistart ATS48 Environment: All Cause: The soft starter is programmed for activation motor underload (ULL) in the Pr0 menu. The motor underload threshold parameter (LUL) is set to 60% and the drive is running only 58% or lower motor torque viewed in the SUP menu parameter (Ltr). Resolution: Troubleshooting: Check Motor underload threshold parameter (LUL) in menu PrO and compare it the motor torque parameter in the SUP menu. If your LUL parameter is set lower then the Ltr in the SUP then the soft starter will trip on ULF fault.