Conduit Glue
Brand Name: Clipsal
Container Size: 125 mL
Container Type: Bottle
Color: Blue
Clipsal Clipsal 240/125BU Glue Conduit Pvc 125Ml Blue - 240/125BU
This item is currently not available for backorder.
We can notify you when it's available again by subscribing to the back in stock notification. Enter your email address and click submit to automatically receive an email when we get more in.
Choose your style, Select your Switch and Checkout
We can customise your powerpoint to a range of colours and layouts, suited to your needs.

SKU | CLI240/125BU |
---|---|
Supplier No | 240/125BU |
EAN / Barcode | 9311554003661 |
Height | 60.000000 |
Length | 73.000000 |
Width | 60.000000 |
Brand | Clipsal |
A FEW FAQS
The part number for a plug to suit the 240/25/3 is a 220/25.
Rating are 240/115V 20va
The only difference between the 240/500BU and the 240/500CL is the colour only. The materials and chemicals used are the same. Some of the key features are: Medium Gap Filling 500ml Bottle Comes with Brush for easy application Available in Clear or Blue For further informaation please visit www.clipsal.com/Trade/Products/ProductDetail?catno=240/500CL
Issue: Implementing a hardwire stepdown transformer in a 208v or 240v environment Product Line: Smart-UPS / Symmetra Environment: APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers Cause: Unbalanced UPS outputs require a stepdown transformer to power 120v loads Resolution: This document refers to installing the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual. The wiring block outputs are as follows: For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position. The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal 7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power. Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.
Unfortunately we dont make U entry junction box any more, closest will be 240/25/2A and similar.
The part number for a 25mm conduit plug is - 220/25 For further information , visit link below:- https://www.clipsal.com/Trade/search-results?q=220/25