Earth Clip
Brand Name: Clipsal
Type: Two Piece Claw
Cable Size: 12.7 mm
Material: Pressed Metal
Finish: Hot Dip Galvanized
Dimensions: 34 mm Length x 26 mm Width
Clipsal Earth Clip 12Mm Brass - 205MBS
This item is currently available for backorder with an estimated arrival time of 2 days
Please note this ETA is provided to us by our suppliers and could potentially be delayed due to factors outside our control. If there are any delays we will contact you to keep you updated.
Choose your style, Select your Switch and Checkout
We can customise your powerpoint to a range of colours and layouts, suited to your needs.

SKU | CLI205MBS |
---|---|
Supplier No | 205MBS |
EAN / Barcode | 9311554048570 |
Height | 10.000000 |
Length | 50.000000 |
Width | 30.000000 |
Brand | Clipsal |
Material | Pressed Metal |
A FEW FAQS
The cut out diameter is 205mm
205mm x 395mm x 155mm (H x W x D) excluding the handle. Overall depth with standard handle is 213mm. See attached.
Max Sell Amps Default - 18Amps (865-1010 XW4024) 36Amps (865-1010-01 XW4024) 27Amps (865-1000 XW6048) 20Amps (865-1005 XW4548) 48Amps (865-1000-01 XW6048) Range - 0-18Amps (865-1010 XW4024) 0-36Amps (865-1010-01 XW4024) 0-27Amps (865-1000 XW6048) 0-20Amps (865-1005 XW4548) 0-48Amps (865-1000-01)
You have several options for relays, Catalogue numbers and information below. L5504RVF, L5504RVFP** - 4 Channel voltage free relay - 10amps per channel L5508RVF, L5508RVFP** - 8 Channel voltage free relay - 10amps per channel L5512RVF, L5512RVFP** - 12 Channel voltage free relay - 10amps per channel L5504RVF20, L5504RVF20P** - 4 Channel voltage free relay - 20amps per channel L5508RELVP - 8 Channel Extra Low Voltage Relay 5101R - Single and Two Channel 250v AC 10amp relay 5102RVF - Single and Two Channel 250v AC 10amp Voltage Free Relay ** Any part number that has a 'P' after the part number for Din Rail mount units does NOT include a C-Bus 200ma Power Supply..
Real time clock accuracy: Accuracy of the real time clock is one second (%SW50) +/- 200ms. Resolution of the real time clock is one second (%SW50) +/- 200ms,because 200ms is the refresh rate of the RTC. Accuracy error: The accuracy error of the quartz oscillator is: 1. At 0 and 70°C : -101/20 ppm, error in second/day is -8.7/1.7, in minute/year is -53/11. 2. At 25°C: -20/20 ppm, error in second/day is -1.7/1.7, in minute/year is -11/11.
Issue: The ACSC100 manual lists an In-Rush current of 56amps for 200ms. How does this not trip the 20amp breaker? Product line: ACSC100 Environment: InRow Cooling Cause: Resolution: The reason that the circuit breaker does not trip is expressed in the time/current curve that are unique properties of circuit breakers or fuses. For example a typical Square ""D"" ""NQ"" breaker rated at 20 amps might trip after 300 seconds of a 20 amp load, but will pass considerably more than 56 amps at 200ms of time.