Conduit Saddle
Brand Name: Clipsal
Type: Half
Nominal Size: 20 mm
Length: 50 mm
Height: 22 mm
Width: 19 mm
Hole Size: 5 mm
Clipsal Saddle Conduit Half 20Mm Zinc Plated - 180/20
This item is currently available for backorder with an estimated arrival time of 2 days
Please note this ETA is provided to us by our suppliers and could potentially be delayed due to factors outside our control. If there are any delays we will contact you to keep you updated.
Choose your style, Select your Switch and Checkout
We can customise your powerpoint to a range of colours and layouts, suited to your needs.

SKU | CLI180/20 |
---|---|
Supplier No | 180/20 |
EAN / Barcode | 9311554038229 |
Width | 19 |
Height | 23.000000 |
Length | 54.000000 |
Width | 25.000000 |
Brand | Clipsal |
Nominal Size | 20mm |
Hole Size | 5 mm |
A FEW FAQS
No, they are only available in grey. This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).
Yes, you can order the 220/20 in white but it needs to be done as a special. For more information, please refer to the link:https://www.clipsal.com/Trade/Products/ProductDetail?catno=220/20
Yes, there is a range of screw caps to suit 56 series plugs and extension sockets. They are 56PC for 3PH 10/20A plugs, 56PCI for 3PH 32-50A plugs ,56PC2 for single phase 10/20A plugs and 56SC2 for single phase extension sockets. For further information please visit https://www.clipsal.com/Trade/search-results?q=56pc or https://www.clipsal.com/Trade/search-results?q=56pc2
203M. Pressed Metal Conduit Fittings, Earth Clips, Water pipe adjustable earth clip 15 - 20mm or 1/2 - 3/4 inch. Please see following link under the documentation tab for full catalogue. https://www.clipsal.com/Trade/Products/ProductDetail?catno=203M
TRACE SW4024 shows Generator under/over speed error The Trace SW4024 120/60hz has a preset AC2 allowable frequency range from (53-67 hz) If there is a frequency out of that range you will get a generator under/over frequency. Solution: Service generator, replace bushings if applicable, and try to reduce max charge rate to see if the remedies the generator input.
Issue: Implementing a hardwire stepdown transformer in a 208v or 240v environment Product Line: Smart-UPS / Symmetra Environment: APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers Cause: Unbalanced UPS outputs require a stepdown transformer to power 120v loads Resolution: This document refers to installing the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual. The wiring block outputs are as follows: For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position. The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal 7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power. Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.