Earth Clip
Brand Name: Clipsal
Type: Two Piece Claw
Cable Size: 20 mm
Material: Pressed Metal
Finish: Hot Dip Galvanized
Dimensions: 42 mm Length x 26 mm Width
Clipsal Earth Clip 20Mm Brass - 207MBS
This item is currently available for backorder with an estimated arrival time of 2 days
Please note this ETA is provided to us by our suppliers and could potentially be delayed due to factors outside our control. If there are any delays we will contact you to keep you updated.
Choose your style, Select your Switch and Checkout
We can customise your powerpoint to a range of colours and layouts, suited to your needs.

SKU | CLI207MBS |
---|---|
Supplier No | 207MBS |
EAN / Barcode | 9311554048617 |
Height | 10.000000 |
Length | 100.000000 |
Width | 70.000000 |
Brand | Clipsal |
Material | Pressed Metal |
A FEW FAQS
Max Sell Amps Default - 18Amps (865-1010 XW4024) 36Amps (865-1010-01 XW4024) 27Amps (865-1000 XW6048) 20Amps (865-1005 XW4548) 48Amps (865-1000-01 XW6048) Range - 0-18Amps (865-1010 XW4024) 0-36Amps (865-1010-01 XW4024) 0-27Amps (865-1000 XW6048) 0-20Amps (865-1005 XW4548) 0-48Amps (865-1000-01)
You have several options for relays, Catalogue numbers and information below. L5504RVF, L5504RVFP** - 4 Channel voltage free relay - 10amps per channel L5508RVF, L5508RVFP** - 8 Channel voltage free relay - 10amps per channel L5512RVF, L5512RVFP** - 12 Channel voltage free relay - 10amps per channel L5504RVF20, L5504RVF20P** - 4 Channel voltage free relay - 20amps per channel L5508RELVP - 8 Channel Extra Low Voltage Relay 5101R - Single and Two Channel 250v AC 10amp relay 5102RVF - Single and Two Channel 250v AC 10amp Voltage Free Relay ** Any part number that has a 'P' after the part number for Din Rail mount units does NOT include a C-Bus 200ma Power Supply..
Real time clock accuracy: Accuracy of the real time clock is one second (%SW50) +/- 200ms. Resolution of the real time clock is one second (%SW50) +/- 200ms,because 200ms is the refresh rate of the RTC. Accuracy error: The accuracy error of the quartz oscillator is: 1. At 0 and 70°C : -101/20 ppm, error in second/day is -8.7/1.7, in minute/year is -53/11. 2. At 25°C: -20/20 ppm, error in second/day is -1.7/1.7, in minute/year is -11/11.
Issue: The ACSC100 manual lists an In-Rush current of 56amps for 200ms. How does this not trip the 20amp breaker? Product line: ACSC100 Environment: InRow Cooling Cause: Resolution: The reason that the circuit breaker does not trip is expressed in the time/current curve that are unique properties of circuit breakers or fuses. For example a typical Square ""D"" ""NQ"" breaker rated at 20 amps might trip after 300 seconds of a 20 amp load, but will pass considerably more than 56 amps at 200ms of time.
Goals and Symptoms Machine worked well with ATV16. But when replaced by ATV28, no run signal received from controller. Controller is open collector output with 24V supply from the ATV. Controller operating sequence is, during initialisation, send a 200mS run signal to the ATV and read the motor encorder for motion. For ATV28 case, there is no run signal at all. Thus the controller detect a encorder feedback error. Could this be due to the ATV28 emit higher level of noise on the 24V supply, thus interfere with the controller operation? Can ATV58 or ATV11 improve the situation? The ATV28 works well when tested independly. Facts and Changes Replace ATV16U41M2 by ATV28HU41M2. Spray painting maching, Causes and Fixes Try to connect the Ov of ATV28 control terminals to the ground. We are very interesting by your problem, is it possible to make some oscillograms of the noise. You can also try to use an external 24v supply Legacy KB System (APS) Data: RESL156482 V3.0, Originally authored by on , Last Edited by on Related ranges: Altivar 28
Goals and Symptoms Machine worked well with ATV16. But when replaced by ATV28, no run signal received from controller. Controller is open collector output with 24V supply from the ATV. Controller operating sequence is, during initialisation, send a 200mS run signal to the ATV and read the motor encorder for motion. For ATV28 case, there is no run signal at all. Thus the controller detect a encorder feedback error. Could this be due to the ATV28 emit higher level of noise on the 24V supply, thus interfere with the controller operation? Can ATV58 or ATV11 improve the situation? The ATV28 works well when tested independly. Facts and Changes Replace ATV16U41M2 by ATV28HU41M2. Spray painting maching, Causes and Fixes Try to connect the Ov of ATV28 control terminals to the ground. We are very interesting by your problem, is it possible to make some oscillograms of the noise. You can also try to use an external 24v supply. Try to use a core on the encoder cable. Legacy KB System (APS) Data: RESL156617 V1.0, Originally authored by on , Last Edited by on Related ranges: Altivar 28