Clipsal Bend Sweep 45Deg Long Sweep 80Mm Orange - 247PH80-EO

Clipsal 247PH80EO Underground Conduit Bend, Long Sweep, 80mm, PVC, 45 Degree, 550mm Radius, Orange
Dispatch. 2 days
Need more?
ITEM (1 qty)
BOX (100 qty)
CARTON (100 qty)
Price
$17.59 $15.99
Your order will have with items each
  • Same Day Dispatch
    Order before midday
  • 60-Day Returns
    stress-free purchasing
  • Full Supplier Warranty
    backed up product quality

Clipsal Bend Sweep 45Deg Long Sweep 80Mm Orange - 247PH80-EO

Clipsal Bend Sweep 45Deg Long Sweep 80Mm Orange - 247PH80-EO
×
  • Clipsal Bend Sweep 45Deg Long Sweep 80Mm Orange - 247PH80-EO
  1. Clipsal Bend Sweep 45Deg Long Sweep 80Mm Orange - 247PH80-EO
Width 160
Height 97
Depth 510
Specification
SKUCLI247PH80EO
Supplier No247PH80-EO
EAN / Barcode9311554154219
StandardsAS/NZS 2053
Width160
Height97.000000
Length510.000000
Width160.000000
BrandClipsal
Nominal Size80 mm

Conduit Bend
Brand Name: Clipsal
Type: Long Sweep
Nominal Conduit Size: 80 mm
Connection Type: Plain
Radius: 580 mm
Angle: 45 deg
Length: 610 mm

A FEW FAQS

Bend Radius for 247PH100 is 715mm

No. Unfortunately, there are not.

No - 45 deg large sweep bends come in orange as the standard colour. For further information please visit https://www.clipsal.com/Trade/search-results?q=247lh32

The part number for the bitsa box is 357TB. Some of the key features are: Tool boxes 12 compartment transparent box with assorted screws, screws and quantities included Includes: 357WF30 (100), 357/20 (150), 357WH12 (350), 357P30 (200), 357P20 (300), 357WH25 (100), 357PH50 (50), 357/63 (50), 357WHP32 (100), 357PH45 (100), 357/35 (100), 357/40 (100) For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=357TB

Issue The iEM3000 series meter documentation does not explicitly specify where and how control power is brought to the meter. Product Line iEM3000 Series Meters Cause To know the maximum voltage to supply, where, and how to wire the supply power. Resolution The iEM3000 series meters derive control power through the meter's phase voltage inputs V1, V2, V3, and Vn. The installation guide for the iEM3000 contains wiring diagrams for different voltage systems. The meters support the direct power Voltage (L-L) 3 x 100/173 V AC to 3 x 277/480 V AC (50/60 Hz) and the direct current measurement up to 63 A or 125 A. Refer to FA352325 for documentation for iEM3000 meters.

Issue A user would like to totalize multiple loads with an Energy meter. Product Line Powerlogic Energy Meter Environment Energy Meter Installation Cause The installation guide for the Energy meter does not contain instructions on wiring the meter to monitor multiple loads. Resolution *Warning: Installation and maintenance of this device should only be performed by qualified, competent personnel that have appropriate training and experience with high voltage and current devices. Failure to follow the instructions / warnings in the Meter Installation Guide can result in permanent damage to the meter, severe injury or death. The Energy meter is calibrated with the set of CTs that are included with the meter, however the Energy Meter can be installed with up to three sets of parallel CTs to monitor multiple loads. When wiring multiple current transformers in parallel to the Energy Meter, all voltages corresponding to the individual loads must be the same voltage values and must be from the same source. The voltage applied to the inputs of the Energy Meter will be used in the power calculations. Monitoring different voltage values and monitoring the same voltage values from different sources will both cause the power calculations to be inaccurate. For example, if load A has a system voltage type of 120/208 VAC, and load B has a system voltage type of 277/480 VAC, an Energy Meter cannot be used to measure both loads in a parallel configuration. Likewise, if Load A and Load B both have a system voltage type of 120/208 VAC, but are supplied their respective voltage from different transformers, an Energy Meter cannot be used to measure both loads in a parallel configuration. Note: When multiple sets of CTs are connected in parallel to the Energy Meter, the accuracy drops from less than 1% to between 1%-3%. Please follow the guidelines in the attached addendum for selecting and installing the parallel CTs on an Energy meter.

We found other products you might like!