The EIB650iC Photoelectric smoke alarm operates on the light scatter principle to detect smoke particles entering the photoelectric chamber.
The automatic dust compensation feature minimises nuisance alarms due to dust build up in the photoelectric chamber. The EIB650iC is supplied with screw fixings with simple to install twist on base. The EIB650iC is fitted with a large easy to use test button to facilitate frequent testing of the alarm. The test button can also be used to silence nuisance alarms, e.g. cooking fumes, for a 10 minute period.
The EIB650iC self-checks its chamber sensor, battery voltage and internal circuitry every 40 seconds. Any fault condition found will be indicated by a combination of Red LED flashes and/or sound beeps.
The EIB650iC is designed with advanced diagnostics to help pre-warn of incumbent fault conditions. The EIB650iC o er a choice of 2 means of interconnection:
- a) wirelessly through the installation of the optional EIB600MRF module fitted into the rear of the smoke alarm.
- b) hardwired through a simple 2 wire terminal block in the base of the Alarm. Other compatible alarms may then be connected.
The AudioLINK feature is a means of extracting alarm specific event data and transmitting acoustically to a unique designed Smart Phone App.