Clipsal Max 4 Link Bar Only 7Hole Neutral - L7P

Brass link bar, 100 A, 500 V, 7 hole
1 In Stock
Need more?
ITEM (1 qty)
BOX ( qty)
CARTON ( qty)
Price
$16.63 $15.12
Same day dispatch ends in : mins
Your order will have with items each
  • Same Day Dispatch
    Order before midday
  • 60-Day Returns
    stress-free purchasing
  • Full Supplier Warranty
    backed up product quality

Clipsal Max 4 Link Bar Only 7Hole Neutral - L7P

Clipsal Max 4 Link Bar Only 7Hole Neutral - L7P
×
  • Clipsal Max 4 Link Bar Only 7Hole Neutral - L7P
  • Clipsal Max 4 Link Bar Only 7Hole Neutral - L7P
  1. Clipsal Max 4 Link Bar Only 7Hole Neutral - L7P
  2. Clipsal Max 4 Link Bar Only 7Hole Neutral - L7P
Width 16
Height 13
Depth 57
Specification
SKUCLIL7P
Supplier NoL7P
EAN / Barcode9318793006712
StandardsAS/NZS 4680
Width40
Height13.000000
Length57.000000
Width16.000000
BrandClipsal
RangeMax4
Clipsal Max 4 Link Bar Only 7Hole Neutral - L7P

Get Max 4 your buck

Complete protection with high performance. With Clipsal Max 4 you will find a range of enclosures, switchboards, residual current devices, miniature circuit breakers, isolators, distribution boards, overvoltage protection and accessories.

A FEW FAQS

no it is now discontinued LUP_ADAPTOR

The part name is 154/2

Issue: What is the difference between LA36400 and LA36400MB? Product Line: Molded Case Circuit Breakers Environment: Legacy LA, LAL, LH, LHL circuit breakers Resolution: The MB breaker has a shorter handle, so that it will not interfere with the door closing on a panel. Note: The MB suffix has a handle that is .325 inches shorter than the standard handle.

Issue: ATV18 driveset up for 2 wire control and low speed as speed reference. Product Line: ATV18, Altivar 18. Environment: All. Cause: Programming and setup. Resolution: 2 wire control for ATV18 drive will be between LI1 and +24V terminals. A maintained dry contact or a jumper can act as a run command. Low speed can be used to control the drive locally. The low speed parameter can be programmed by hitting down arrow key on the drive until LSP is shown. Once LSP shows up press data and use the up and down arrow keys to adjust setting. Once satisfied with speed press enter to save the setting.

Issue: Installation manual needed for an Altivar 61 Drive Product line: Altivar 61 Environment: All models, all serial numbers Cause Installation manual is not shipped with the drive. Resolution: There are two Installation manuals for the ATV61 drives, Low HP (up to 100HP) and High HP (above 100HP). The installation manual for the Altivar 61 drives up to and including 100 Horsepower can be found at this link: https://www.schneider-electric.us/en/download/document/1760643/ The installation manual for the Altivar 61 drives above 100 Horsepower can be found by following this link: https://www.schneider-electric.us/en/download/document/1760655/

Issue: Removal of bottom cover on ATV61 and ATV71. Product Line: Altivar ATV61 and ATV71 LHP units only or under 90KW Environment: All Cause: They can not get the the bottom cover off to check the power terminals. Resolution: 1st Turn off all power make sure the drive is not powered up and the DC bus is discharged before starting. You will need to turn the set screw counter clockwise on the control terminal pod. Next use a flat head screw drive to pry the corners on each side the cover to see if you can work it loose. Then pull down cover to remove it. This procedure is demonstrated in the video below: