Clipsal Clipsal 240/125CL Glue Conduit Pvc 125Ml Clear - 240/125CL

Clipsal 240/125CL PVC Conduit Glue, Medium Gap Filling Cement, 125ml Bottle With Brush, Clear
0 In Stock
Need more?
ITEM (1 qty)
BOX (N/A qty)
CARTON (18 qty)
Price
$3.62 $3.29

Clipsal Clipsal 240/125CL Glue Conduit Pvc 125Ml Clear - 240/125CL

Clipsal Clipsal 240/125CL Glue Conduit Pvc 125Ml Clear - 240/125CL
×
  • Clipsal Clipsal 240/125CL Glue Conduit Pvc 125Ml Clear - 240/125CL
  1. Clipsal Clipsal 240/125CL Glue Conduit Pvc 125Ml Clear - 240/125CL
Width 60
Height 60
Depth 75
Specification
SKUCLI240/125CL
Supplier No240/125CL
EAN / Barcode9311554003623
Height60.000000
Length75.000000
Width60.000000
BrandClipsal

Conduit Glue
Brand Name: Clipsal
Container Size: 125 mL
Container Type: Bottle
Color: Clear

A FEW FAQS

The part number for a plug to suit the 240/25/3 is a 220/25.

Rating are 240/115V 20va

The only difference between the 240/500BU and the 240/500CL is the colour only. The materials and chemicals used are the same. Some of the key features are: Medium Gap Filling 500ml Bottle Comes with Brush for easy application Available in Clear or Blue For further informaation please visit www.clipsal.com/Trade/Products/ProductDetail?catno=240/500CL

Issue: Implementing a hardwire stepdown transformer in a 208v or 240v environment Product Line: Smart-UPS / Symmetra Environment: APTF10KT01, APTF10KW01, and APTF20KW01, All Serial Numbers Cause: Unbalanced UPS outputs require a stepdown transformer to power 120v loads Resolution: This document refers to installing the APTF10KT01, APTF10KW01, and APTF20KW01 transformers in a North American 120/240 or 120/208 environment. For installations in other regions please consult the users manual. The wiring block outputs are as follows: For domestic use, make sure that the Terminal Block Jumper is installed between the Ground Terminal and Terminal 8 on the output wiring block, as illustrated on page 8 of the user manual. Please also make sure that the input voltage switch is in the correct position. The step-down transformer provides 240/120 output as 2 120v hots, a neutral, and a ground. It provides 208v output as a 120v hot, an 88v hot, and a ground. The 120v hot (terminal 7) and the 88v hot (terminal 9) are 180 degrees out of phase. You will measure 208v from terminals 7 to 9. The step-down transformer is not able to provide 2 120v hots that are 120 degrees out of phase as you would see with utility power. Note: If your installation requires both 208v and 120v output power you will need 2 separate subpanels: a 240v/120v panel and a dedicated 208v subpanel.

Unfortunately we dont make U entry junction box any more, closest will be 240/25/2A and similar.

We found other products you might like!