Clipsal Saddle Conduit Half 20Mm Zinc Plated 180A20 - 180A20

Clipsal 180A20 Half Saddle, Conduit Clip, With 6.5mm Hole, 20mm, Zinc Plated Steel
58 In Stock
Need more?
ITEM (1 qty)
BOX (100 qty)
CARTON (1000 qty)
Price
$0.42 $0.38
Same day dispatch ends in : mins
Your order will have with items each
  • Same Day Dispatch
    Order before midday
  • 60-Day Returns
    stress-free purchasing
  • Full Supplier Warranty
    backed up product quality

Clipsal Saddle Conduit Half 20Mm Zinc Plated 180A20 - 180A20

Clipsal Saddle Conduit Half 20Mm Zinc Plated 180A20 - 180A20
×
  • Clipsal Saddle Conduit Half 20Mm Zinc Plated 180A20 - 180A20
  • Clipsal Saddle Conduit Half 20Mm Zinc Plated 180A20 - 180A20
  • Clipsal Saddle Conduit Half 20Mm Zinc Plated 180A20 - 180A20
  1. Clipsal Saddle Conduit Half 20Mm Zinc Plated 180A20 - 180A20
  2. Clipsal Saddle Conduit Half 20Mm Zinc Plated 180A20 - 180A20
  3. Clipsal Saddle Conduit Half 20Mm Zinc Plated 180A20 - 180A20
Width 20
Height 20
Depth 49
Specification
SKUCLI180A20
Supplier No180A20
EAN / Barcode9311554038281
Width19
Height20.000000
Length49.000000
Width20.000000
BrandClipsal
Nominal Size20mm
Hole Size6.5 mm

Conduit Saddle
Brand Name: Clipsal
Type: Half
Nominal Size: 20 mm
Length: 50 mm
Height: 22 mm
Width: 19 mm
Hole Size: 6.5 mm

A FEW FAQS

No, they are only available in grey. This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

Issue: Disconnecting and Reconnecting a Configured RS232-Based Sensor or Output Control Device Can Cause Device Settings to be Lost Product Line: NetBotz Environment: NetBotz and RS232 sensor connections Cause: Settings associated with RS232-based sensors or output control devices may not be preserved if the device is disconnected and then reconnected. Resolution: Once you have connected and configured settings for an RS232-based sensor or device, do not disconnect or relocate this device unless you are prepared to reconfigure the device.

Issue: Can the full weight of the NetShelter cabinet rest on the leveling feet? Product Line: NetShelter SX Environment: All versions and serial ranges. Cause: Cabinets are leveled using the leveling feet so they need to bear the full weight of the cabinet and it's contents. (static load rating) Resolution: Yes, the leveling feet can support the cabinet up to the rated static load rating of the cabinet. FAQ FA158656 also contains information regarding shipping load, dynamic load and static load ratings.

Issue: Filter for bearing current reductions for the ATV600 and ATV900. Product Line: ATV600 and ATV900 drives frame size 6 Environment: All Cause: Filter for bearing current reductions Resolution: The part number is VW3A5504 and its value of inductance is 180.0 uH

Issue What are the battery replacement options for the Smartcell battery pack? Product Line Matrix UPS Environment Matrix UPS with SMARTCELL battery packs Cause APC has discontinued the SMARTCELL battery pack due to lack of availability of unique parts required to build it. Resoluiton In order to continue to support the use of the Matrix battery pack, APC has teamed up with Coastal Business Machines, a certified pre-owned partner, to offer refurbished sales and service of the SMARTCELL battery packs. Options for replacing the SMARTCELL battery pack CoastTec is the only authorized refurbisher of the SMARTCELL. They offer 2 options for customers looking to continue using the Matrix-UPS system. Option 1: Purchase a refurbished SMARTCELL pack, which includes return shipping and disposal of the old battery pack (if applicable). Option 2: Send your existing SMARTCELL pack into CBMs service center for reconditioning. This option also includes inbound shipping of the old battery pack.

Issue: During the install for PME 9.0 user gets error at Verify Databases step. This is shown in the picture below. The Installation Log contains the following error: ""END OF POST-DEPLOYMENT STAGE" was NOT found in C:\Program Files (x86)\Schneider Electric\Power Monitoring Expert\Database\Diagnostic\ION_Data_Upgrade.log" The ION_Data_Upgrade.log file contains the following: Changed database context to 'master'. Creating ION_Data... Msg 5123, Level 16, State 1, Server VWMERION01P\ION, Line 1 CREATE FILE encountered operating system error 5(Access is denied.) while attempting to open or create the physical file 'C:\Program Files (x86)\Schneider Electric\Power Monitoring Expert\Database\ION_Data.MDF'. Msg 1802, Level 16, State 4, Server VWMERION01P\ION, Line 1 CREATE DATABASE failed. Some file names listed could not be created. Check related errors. Product: PME 9.0 Resolution: Add the windows user running the installer to the Schneider Electric -> Power Monitoring Expert folder with full control. This can be done by right clicking on the folder and going to Properties -> security.

We found other products you might like!