Clipsal Saddle Conduit Half 32Mm Zinc Plated - 180/32

Clipsal 180/32 Half Saddle, Conduit Clip, 32mm, Zinc Plated Steel
56 In Stock
Need more?
ITEM (1 qty)
BOX (50 qty)
CARTON (500 qty)
Price
$0.37 $0.34
Same day dispatch ends in : mins
Your order will have with items each
  • Same Day Dispatch
    Order before midday
  • 60-Day Returns
    stress-free purchasing
  • Full Supplier Warranty
    backed up product quality

Clipsal Saddle Conduit Half 32Mm Zinc Plated - 180/32

Clipsal Saddle Conduit Half 32Mm Zinc Plated - 180/32
×
  • Clipsal Saddle Conduit Half 32Mm Zinc Plated - 180/32
  • Clipsal Saddle Conduit Half 32Mm Zinc Plated - 180/32
  • Clipsal Saddle Conduit Half 32Mm Zinc Plated - 180/32
  1. Clipsal Saddle Conduit Half 32Mm Zinc Plated - 180/32
  2. Clipsal Saddle Conduit Half 32Mm Zinc Plated - 180/32
  3. Clipsal Saddle Conduit Half 32Mm Zinc Plated - 180/32
Width 35
Height 29
Depth 70
Specification
SKUCLI180/32
Supplier No180/32
EAN / Barcode9311554038243
Width24
Height29.000000
Length70.000000
Width35.000000
BrandClipsal
Nominal Size32mm
Hole Size7 mm

Conduit Saddle
Brand Name: Clipsal
Type: Half
Nominal Size: 32 mm
Length: 67 mm
Height: 33 mm
Width: 24 mm
Hole Size: 7 mm

A FEW FAQS

No, they are only available in grey. This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

The PDL 680M32 (switch module, 1 way, 2 terminal, 32A, 240V) is only available in white or black. https://www.pdl.co.nz/product-details.aspx?rcat=products&catid=0&id=825

Code = A9E18073

Issue How to write a command to a modbus register within the PowerLogic PM800 series meter to reset the peak demand. Product Line PowerLogic PM800 series meter Environment Microsoft Windows, Modbus Tester Tool Cause A customer may be required to reset the peak demand on his meter. Resolution To reset peak demand values, write the value 5210 to register 8000 on the PM800 series meter using the Modbus Tester Tool. To read/write registers using the Modbus Tester Tool, please refer to KB: FA 180037 - What is Modbus Tester and how do I use it?

Issue: Error When Attempting a Runtime Calibration in PowerChute Business Edition Product Line: PowerChute Business Edition Environment: All supported OS Cause: 1) The battery has less than 100% charge: 2) The load on the UPS is 10% or less: Resolution: Two conditions need to be met in order to perform a calibration: 1) The battery charge needs to be at 100%, 2) The load on the UPS needs to be greater than 10% of the battery capacity

Issue: What is the fuse or circuit breaker rating for LXM32 drives? Product Line: LXM32 Resolution: For 115VAC and 230VAC drives, the maximum fuse to be connected upstream is 25 Amps, Class CC or J as per UL 248-4, alternatively circuit breakers with B or C characteristic. For 400VAC and 480VAC drives, the maximum fuse to be connected upstream is 30/32 Amps, Class CC or J as per UL 248-4, alternatively circuit breakers with B or C characteristic.

We found other products you might like!