Clipsal Bracket 1 Gang Standard Pattern Horizontal with Nails - 155N

Clipsal 155N Stud Mounting Bracket, Metal, Standard Pattern, Horizontal, With Fixing Nails, 1Gang
37 In Stock
Need more?
ITEM (1 qty)
BOX (20 qty)
CARTON (200 qty)
Price
$0.86 $0.78
Same day dispatch ends in : mins
Your order will have with items each
  • Same Day Dispatch
    Order before midday
  • 60-Day Returns
    stress-free purchasing
  • Full Supplier Warranty
    backed up product quality

Clipsal Bracket 1 Gang Standard Pattern Horizontal with Nails - 155N

Clipsal Bracket 1 Gang Standard Pattern Horizontal with Nails - 155N
×
  • Clipsal Bracket 1 Gang Standard Pattern Horizontal with Nails - 155N
  1. Clipsal Bracket 1 Gang Standard Pattern Horizontal with Nails - 155N
Width 72
Height 35
Depth 140
Specification
SKUCLI155N
Supplier No155N
EAN / Barcode9311554036232
Width72
Height35.000000
Length140.000000
Width72.000000
BrandClipsal
RangeClipsal Accessories
Number of Switches1 Gang
MaterialSteel

Mounting Bracket With Nails
Brand Name: Clipsal
Type: Standard Pattern
Gang: 1
Length: 135 mm
Width: 72 mm
Depth: 37 mm
Material: Steel
Finish: Electro Galvanized
Shape: Rectangular
Mounting Direction: Horizontal

A FEW FAQS

The part number for Optiline 70 skirting duct 155x 55 is a - ISM11450 For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=ISM11450

Issue: How to read a LXM32 drive ramp (ACC, DEC) using SoMachine? Product Line: Lexium 32 Resolution: To read the drive ramp values (ACC, DEC), you can use the function block "MC_ReadParameter". This function block requires the modbus address of the parameter in the input "Address". ParameterNumber must be set to 1000 (Default value). 1556 = RAMP_v_acc 1558 = RAMP_v_dec Using GetAttributeSingle would also work. In this case, the CIP address should be used (can be found in the LXM32M manual). CIP 106.1.10 = RAMP_v_acc CIP 106.1.11 = 1558 = RAMP_v_dec

Issue: When is a neutral CT required? Product Line: Environment: Cause: Resolution: A neutral CT is only required when there are loads that produce neutral current. A neutral CT is required when an electronic-trip circuit breaker has a ground-fault option (alarm or trip) and is used on a 4 wire system. Neutral current must be factored in with phase current for accurate sensing. A neutral CT is also required for the GFM modules when used on a 4-wire system. CTA-ID : 1559

The larges is Actassi 155 x 55 part code ISM11400

PDL56DOL12LOBGY - less overload available on page 155 Pocket book PDL 2014

Goals and Symptoms The purpose of this resolution is to inform the user on the behavior when using the command GetIDN_S (opcode 1556) or Get IDN_P ( opcode 1557 ) from a Quantum (or) a Premium SERCOS Controller. Facts and Changes When a 2 bytes IDN is gets the PLC haven't any possibility to know if the value is signed or not. So, the PLC register accommodate values from -32767 to + 32767 in signed format Due to the above reason, values for IDN_S ( or _P ) 2 bytes set higher than 32767 when read, will be returned as follows: (i) 32768 -> -32768 (ii) 32769-> -32767 (iii) 35000 -> -30536 in signed format. Unsigned format will result in a huge number. Causes and Fixes When GetIDN_S ( or _P ) returns a negative value, it may be converted to its positive equivalent by adding 65536. For example, -30536 + 65536 = 35000 and so on. There is no implication on using the SetIDN_S ( or _P) command for the same IDN which is Unsigned decimal format. Legacy KB System (APS) Data: RESL182198 V1.0, Originally authored by PhBr on 02/16/2007, Last Edited by PhBr on 02/16/2007 Related ranges: Modicon Premium

We found other products you might like!