Schneider Electric TeSys D Tesys D Contactor - 4P(4 No) - Ac-1 - <= 440 V 25 A - 240 V Ac 50/60 Hz Coil - LC1DT25U7

Tesys D Contactor - 4P(4 No) - Ac-1 - <= 440 V 25 A - 240 V Ac 50/60 Hz Coil
Dispatch. 2 days
Need more?
ITEM (1 qty)
BOX ( qty)
CARTON ( qty)
Price
$154.22 $140.20
Your order will have with items each
  • Same Day Dispatch
    Order before midday
  • 60-Day Returns
    stress-free purchasing
  • Full Supplier Warranty
    backed up product quality

Schneider Electric TeSys D Tesys D Contactor - 4P(4 No) - Ac-1 - <= 440 V 25 A - 240 V Ac 50/60 Hz Coil - LC1DT25U7

Clipsal TeSys D Tesys D Contactor - 4P(4 No) - Ac-1 - <= 440 V 25 A - 240 V Ac 50/60 Hz Coil - LC1DT25U7
×
  • Clipsal TeSys D Tesys D Contactor - 4P(4 No) - Ac-1 - <= 440 V 25 A - 240 V Ac 50/60 Hz Coil - LC1DT25U7
  1. Clipsal TeSys D Tesys D Contactor - 4P(4 No) - Ac-1 - <= 440 V 25 A - 240 V Ac 50/60 Hz Coil - LC1DT25U7
Width 950
Height 550
Depth 1180
Specification
SKUSCHLC1DT25U7
Supplier NoLC1DT25U7
EAN / Barcode3389110577686
Width45
Height550.000000
Length1180.000000
Width950.000000
BrandClipsal
RangeTeSys
Voltagepower circuit: <= 690 V AC 25...400 Hz
Durability0.8 Mcycles 25 A AC-1 at Ue <= 440 V
TeSys D contactor, 4 poles (4NO), for non-inductive load applications up to 25A/690V AC-1. It provides a 240V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

A FEW FAQS

Issue: Identifying replacement coils for tesys D non-reversing and reversing conactors Product Line: IEC Contactors and Starters Environment: Products sold and used in the United States Cause: Replacement coil is needed Resolution: DC replacement coils are not available. AC Coils are 50/60 hertz for voltages as listed below: Volts - Part Number 12 ____ LXD1J7 21 ____ LXD1Z7 24 ____ LXD1B7 32 ____ LXD1C7 36 ____ LXD1CC7 42 ____ LXD1D7 48 ____ LXD1E7 60 ____ LXD1EE7 100 ___ LXD1K7 ( never brought to North America ) 110 ___ LXD1F7 115 ___ LXD1FE7 120 ___ LXD1G7 127 ___ LXD1FC7 200 ___ LXD1L7 208 ___ LXD1LE7 220 ___ LXD1M7 230 ___ LXD1P7 240 ___ LXD1U7 277 ___ LXD1W7 380 ___ LXD1Q7 400 ___ LXD1V7 415 ___ LXD1N7 440 ___ LXD1R7 480 ___ LXD1T7 575 ___ LXD1SC7 600 ___ LXD1X7 690 ___ LXD1Y7 Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil.

Issue: Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor Product Line: Tesys D Contactors Environment: IEC contactors Resolution: The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section). They are next to the auxiliary contact (13/14, 21/22) terminals.

Issue: Identifying maximum voltage of an LC1D contactor Product Line: TeSys D Contactors Environment: IEC contactors and starters used in North America Cause: n/a Resolution: IThe maximum voltage per UL and CSA is 600VAC.

Issue: Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors Product Line: IEC Contactors and Starters Environment: Tesys D Contactors Resolution: For contactors with screw clamp terminals: stranded cable w/o cable end : One or Two #18-10 AWG per terminal. stranded cable w/cable end: One or Two #18-10 AWG per terminal. solid cable: One or Two #18-8 AWG per terminal.

Issue: What is the altitude derating for a TeSys D-Line contactor? Product Line: Digest 177 Section 18 : Contactors and Starters, IEC Environment: North American Products Resolution: The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current: Voltage 3500m x 0.90 4000m x 0.80 4500m x 0.70 5000m x 0.60 Current 3500m x 0.92 4000m x 0.90 4500m x 0.88 5000m x 0.86 For example, an LC1D80 at 5000 meters: - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA). - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.

Issue: Mounting adaptor for GV2 and LC1D contactor Product Line: Motor Starters and Protectors Environment: TeSys GV Manual Starter and Protectors Tesys D Contactors Resolution: The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

We found other products you might like!