Clipsal PowerTag Powertag Wiser M63 3P - 4CBEM3

energy sensor, PowerTag Wiser Energy Monoconnect 63A 3P top and bottom
2 In Stock
Need more?
ITEM (1 qty)
BOX ( qty)
CARTON ( qty)
Price
$153.56 $139.60
Same day dispatch ends in : mins
Your order will have with items each
  • Same Day Dispatch
    Order before midday
  • 60-Day Returns
    stress-free purchasing
  • Full Supplier Warranty
    backed up product quality

Clipsal PowerTag Powertag Wiser M63 3P - 4CBEM3

Clipsal PowerTag Powertag Wiser M63 3P - 4CBEM3
×
  • Clipsal PowerTag Powertag Wiser M63 3P - 4CBEM3
  • Clipsal PowerTag Powertag Wiser M63 3P - 4CBEM3
  • Drag image to spin
  1. Clipsal PowerTag Powertag Wiser M63 3P - 4CBEM3
  2. Clipsal PowerTag Powertag Wiser M63 3P - 4CBEM3
  3. Clipsal PowerTag Powertag Wiser M63 3P - 4CBEM3
Width 600
Height 500
Depth 850
Specification
SKUCLI4CBEM3
Supplier No4CBEM3
EAN / Barcode3606489524692
Width830
Height500.000000
Length850.000000
Width600.000000
BrandClipsal
RangePowerTag
Clipsal PowerTag Powertag Wiser M63 3P - 4CBEM3

PowerLogic PowerTag Control

PowerTag Control monitors circuits wirelessly, collecting status of daisy-chained circuit breakers and notifying the data concentrator of information status, such as OF, SD, Contractor or Impulse Relay position indication. These wireless input/ output modules allow circuit control and status monitoring. Designed for use in commercial and building applications, they quickly and easily turn your distribution board into a connected panel.

PowerTag Control also connects to pulse relays or contactors for remote control within a building management system for non-critical loads, such as lighting.

A FEW FAQS

Goals and Symptoms Goal To add the ITIC / CBEMA webpage option to the ECC21. Causes and Fixes Cause By default the ECC21 card does not have the CBEMA curve webpage pre-loaded Resolution FTP the ITIC.htm file to the ECC21 to enable ITIC / CEBEMA graphs 1. Download the attached ITIC.htm file to the root of C:\ 2. Open a Windows Command Prompt (cmd) 3. Enter "ftp xxx.xxx.xxx.xxx" where the x's correspond to the IP address of the ECC21 4. When prompted, enter the ECC user name "admin" 5. When prompted, enter the admin password. The default password is "admin" 6. Enter "send C:\itic.htm" Example ITIC graph

Issue: "SMC" series Smart-UPS switches to battery when it encounters high input voltage. Product line: Smart-UPS SMC Environment: SMC1000, SMC1500, SMC1000-2u, SMC1500-2u Cause: The SMC series of Smart-UPS feature boost-only voltage regulation. If input voltage rises above your high voltage transfer point, the UPS will switch to on-battery operation. This is normal. Resolution: If you find your unit repeatedly switching to on-battery operation due to high input voltage, you can adjust the high voltage transfer point via Powerchute Business Edition. This gives you a wider range of acceptable input voltages and will allow your UPS to stay on-line in a wider variety of situations. Please note that this will also potentially expose your attached load to higher voltages, however it will never expose your load to anything outside of CBEMA standards for acceptable input voltage. If your application requires both boost and trim voltage regulation, we would suggest upgrading to an SMT or SMX series Smart-UPS.

Issue The CBEMA log and the power quality report for the ION8650 indicate that a PQ event but the PQDIF extractor in PME 8.x creates an empty file for the specific time range. Product line ION8650C, PME 8.1 Environment PQDIF extractor Cause The ION8650's Sag/swell module doesn't have following outputs and therefore they are not logged in the database. 1- SubV1Avg, SubV2Avg, SubV3Avg 2- DistV1Avg, DistV2Avg, DistV3Avg The PQDIFF extractor default templates for the ION8650 meters requires a disturbance average quantity in order to generate a PQDIFF file. Resolution The ION8650C, unlike the ION8650A and ION8650B, was not designed to be a power quality meter and has limited PQ capabilities. The meter by default records the min and max duration and the PQDIFF extractor can be modified to export PQDIFF files from the ION8650C: To Add a new custom template to PQDIFF that can export either the min or max disturbance values: Navigate to PME_Directory\Schneider Electric\Power Monitoring Expert\config\exporters\PQDIF\templates Add the files SagSwell_Voltage_Disturbance_max_values and SagSwell_Voltage_Disturbance_min_values to the folder. Restart the ION PQDIF Exporter Service and relaunch PQDIF exporter. Select the new ION8650C templates and then run an export job in PQDIF exporter The extracted files will contain either the mix or the min values.

Issue An ION Enterprise 5.6 SP1 or 6.0, StruxureWare Power Monitoring (SPM), Power Monitoring Expert (PME) system which includes a PM850 or PM870 device, the device reboots periodically for no apparent reason. Product Line PM850 PM870 Environment ION Enterprise 5.6 SP1, StruxureWare Power Monitoring (SPM), Power Monitoring Expert (PME) PM850 PM870 Cause There is a problem with firmware versions for PM8 devices prior to v10.8 which can cause the device to reboot if it is polled frequently. Resolution Upgrade the meter firmware to version 10.8 or greater. Upgrading the meter firmware will also allow the device to provide information required for a CBEMA plot. Access to firmware upgrade instructions, including a how-to video and a link to the latest firmware can be found at: Firmware Upgrade - Instructions and Downloads If only the firmware is required, it can be downloaded directly from: https://www.schneider-electric.com/en/download/document/PM8xx_V12.5/ Or Alternatively, 1) Using a internet browser navigate to www.schneider-electric.com 2) select Support, then Download Center from the Green menu bar 3) type "PM800 Series V12.500 Firmware" into the search bar and click on the Search button 4) click on the "PM800 Series V12.500 Firmware" link presented in the search results 5) click on the Download button to start the download and save the file Note: Also by entering only PM800 and/or keyword search criteria into the search bar, you be find wide variety of PM800 related documents.

We found other products you might like!