Clipsal Max 4 Link Bar Only Neutral - L12P
This item is currently available for backorder with an estimated arrival time of 2 days
Please note this ETA is provided to us by our suppliers and could potentially be delayed due to factors outside our control. If there are any delays we will contact you to keep you updated.
Choose your style, Select your Switch and Checkout
We can customise your powerpoint to a range of colours and layouts, suited to your needs.
Clipsal Max 4 Link Bar Only Neutral - L12P
SKU | CLIL12P |
---|---|
Supplier No | L12P |
EAN / Barcode | 9318793005661 |
Standards | IEC 61557-12 |
Width | 23 |
Height | 13.000000 |
Length | 80.000000 |
Width | 12.000000 |
Brand | Clipsal |
Range | Max4 |
Number of Poles | 1 Pole + Neutral |
Voltage | 200...240 V AC |
Mounting | Top |
Get Max 4 your buck
Complete protection with high performance. With Clipsal Max 4 you will find a range of enclosures, switchboards, residual current devices, miniature circuit breakers, isolators, distribution boards, overvoltage protection and accessories.
A FEW FAQS
The black cover is the L10.
Issue: Programming ATV212 Drive Product line: ATV212 or S-Flex Environment: All models, all serial numbers Cause: Basic Programming for the ATV212 drive. Resolution: *First set TYP to 2 for 60 hz motors (doing this first will pre-set many of the other parameters). Program the following drive parameters: CNOD - START/STOP 0 = Terminals (most common) 1 = HMI (keypad Run/Stop buttons) 2 = Communications (Serial Communication) FNOD - Frequency reference 1 - Ref Source VIA (4-20mA or 0-10VDC) 2 - Ref Source VIB (0-10VDC) 3 - HMI reference (keypad) 4 - Serial Com Ref 5 - +/- Speed AU1 - Auto Ramp Adapt (default is 1, ALWAYS change to 0 unless you understand what it does) ACC - Acceleration in seconds DEC - Deceleration in seconds FH - Max Frequency UL - Upper Limit Frequency (High Speed) LL - Lower limit Frequency (Low Speed) uL - Rated motor frequency uLu - Rated motor Voltage tHr - Motor thermal protection ( Full load amps of the motor, for overload protection) F111 - Terminal F logic input assignment (Programmable input, default = 2; run forward) F112 - Terminal R logic input assignment (Programmable input, default = 6; preset speed) F113 - Terminal RES logic input assignment (Programmable input, default = 10; fault reset) F415 - Rated motor current (Full Load amps of the motor) F417 - Rated motor speed (Motor rpms) F601 - Current Limit ( Full load amps of the motor multiplied by the service factor of the motor) F201 thru F204 scaling the analog input for VIA (sets scale of analog input VIA) F210 thru F213 scaling the analog input for VIB (sets scale of analog input VIB) F201=VIA speed ref level 1 (%) If using 4-20mA, set to 20%. If using 0-10V, set to 0% F202=VIA output frequency level 1 (Hz) For 4-20mA set to 0, For 0-10V set to 0 F203= VIA speed ref level 2 (%) Set to 100% unless you're using less than 10V or 20mA F204= VIA output frequency level 2 (Hz) Set according to max speed (60Hz in the US) F210=VIB speed ref level 1 (%) For 0-10V set this to 0% F211=VIB output frequency level 1 (Hz) For 0-10V set this to 0 F212= VIB speed ref level 2 (%) For 0-10V set this to100%. If using 0-5V, set this to 50% F213= VIB output frequency level 2 (Hz) Set according to max speed (60Hz in the US) There are many other settings and functions available. Note that S-Flex enclosed drives may have different default values than listed here since the programming is often modified to match the wiring in the enclosure. Refer to the ATV212 Programming manual S1A53838 for further details.