Clipsal Saddle Conduit Half 40Mm Zinc Plated - 180/40

Clipsal 180/40 Half Saddle, Conduit Clip, 40mm, Zinc Plated Steel
78 In Stock
Need more?
ITEM (1 qty)
BOX (50 qty)
CARTON (250 qty)
Price
$0.62 $0.56
Same day dispatch ends in : mins
Your order will have with items each
  • Same Day Dispatch
    Order before midday
  • 60-Day Returns
    stress-free purchasing
  • Full Supplier Warranty
    backed up product quality

Clipsal Saddle Conduit Half 40Mm Zinc Plated - 180/40

Clipsal Saddle Conduit Half 40Mm Zinc Plated - 180/40
×
  • Clipsal Saddle Conduit Half 40Mm Zinc Plated - 180/40
  • Clipsal Saddle Conduit Half 40Mm Zinc Plated - 180/40
  • Clipsal Saddle Conduit Half 40Mm Zinc Plated - 180/40
  1. Clipsal Saddle Conduit Half 40Mm Zinc Plated - 180/40
  2. Clipsal Saddle Conduit Half 40Mm Zinc Plated - 180/40
  3. Clipsal Saddle Conduit Half 40Mm Zinc Plated - 180/40
Width 32
Height 39
Depth 74
Specification
SKUCLI180/40
Supplier No180/40
EAN / Barcode9311554038250
Width32
Height39.000000
Length74.000000
Width32.000000
BrandClipsal
Nominal Size40mm
Hole Size7 mm

Conduit Saddle
Brand Name: Clipsal
Type: Half
Nominal Size: 40 mm
Length: 74 mm
Height: 41 mm
Width: 32 mm
Hole Size: 7 mm

A FEW FAQS

No, they are only available in grey. This applies to the 280/16 (16mm), 280/20 (20mm), 280/25 (25mm), 280/32 (32mm), 280/40 (40mm) and 280/50 (50mm).

TRACE SW4024 shows Generator under/over speed error The Trace SW4024 120/60hz has a preset AC2 allowable frequency range from (53-67 hz) If there is a frequency out of that range you will get a generator under/over frequency. Solution: Service generator, replace bushings if applicable, and try to reduce max charge rate to see if the remedies the generator input.

Issue Need drawings of Sepam 20/40 Feeder, Sepam 20/40 Main and Sepam 80 Main/Feeder. Product Line Sepam 20 Series Sepam 40 Series Sepam 80 Series Resolution See attachment for drawings.

Issue: Customer is installing the Conext SW and wants to confirm the wiring of the AC and DC cabling. Environment: Conext SW 2524 120/240 Split-phase (865-2524) Conext SW 4024 120/240 Split-phase (865-4024) Resolution: See the attached wiring diagrams for the Conext SW and Conext SW-NA. Do not mix AC and DC wiring in the same conduit or panel. Consult the applicable installation code for details. There are two dual 3/4" /1" trade-size knockouts on the side panel and another two on the bottom panel for AC wiring. Use the same trade size of strain relief as the trade size of the knockout(s) you are using.

Issue Sepam relays can connect to any standard voltage transformer (VT) with a rated secondary voltage of 100240 V. Square D offers a wide range of voltage transformers: to measure phase-to-neutral voltages: VT with 1 insulated MV terminal to measure phase-to-phase voltages: VT with 2 insulated MV terminals with or without integrated protection fuses The CCT640 connects the four additional voltages available in Sepam B83. It provides impedance matching and isolation between the voltage transformers and the input circuits of the Sepam relay. The connection port (B2) is not visible in Figure 1, behind the CCT640. see attachment:

Issue: Parameter FbS (feedback scale factor) Product Line: ATV31 and ATV312 Environment: All models and serial numbers Cause: None Resolution: The parameter FbS is a parameter that can be used to scale the reference according to the range of the feedback sensor. Example: Regulating pressure PI reference range of process, 0-50 psi (0-100%) Range of pressure sensor, 0-100 psi FbS = Max sensor range / Max process range FbS = 100/50 = 2

We found other products you might like!