Clipsal Iconic Series 2 Switches - 10 A - Vertical - Ip44 - Vivid White - 3042V44-VW

Clipsal Iconic Series 2 Switches - 10 A - Vertical - Ip44 - Vivid White - 3042V44-VW

Price
$51.74 $47.04
Dispatch. 2 days
3042V44-VW
Clipsal 3042V44VW Iconic Series Switch, Single Pole, Flush, IP44, 2 Gang, Vertical, 250V 10AX, 1 or 2 Way, White Electric
Complete Product
Clipsal Iconic Series 2 Switches - 10 A - Vertical - Ip44 - Vivid White - 3042V44-VW
  • Clipsal Iconic Series 2 Switches - 10 A - Vertical - Ip44 - Vivid White - 3042V44-VW
×
  • Clipsal Iconic Series 2 Switches - 10 A - Vertical - Ip44 - Vivid White - 3042V44-VW
  1. Clipsal Iconic Series 2 Switches - 10 A - Vertical - Ip44 - Vivid White - 3042V44-VW
Width 77
Height 35
Depth 120
Full Box -
Full Carton -
Full Pallet -

Specification
SKUCLI3042V44VW
RangeIconic Series
Length Packaging120.2
Height Packaging35.02
Depth Packaging77.8
Width77.800000
Height35.020000
Depth120.200000
BrandClipsal
Supplier No3042V44-VW
Current Rating10 Amps
ColourVivid White
Colour CodeVW
Number of Switches2
Mechanisms10 Amps
OrientationVertical
EAN / Barcode9311554785871
Complete ProductYes

Clipsal Iconic Switch, Vertical, 2 Gang, 1/2 Way, 10AX, 250V, IP44

Customisable and future-ready

Iconic is based around a unique, electrically safe grid plate, with a choice of three different skin designs that simply clip on top.

Once the grids have been installed by an electrician, it’s safe for anyone to change the skins at any time. Simply clip off the standard skins and clip on the new design.

Interchangeable standard, Styl and Essence skins provide great options to customise to suit specific decor and lifestyle.

FAQ

Part number comes standard as Vivid White, will need Cool Grey cover to suit.

Issue: Checking if the 9001KY3 enclosure is available with an extra conduit entry in the top Product Line: Push Buttons and Operator Interface Environment: 9001KY/SKY Control Stations Cause: Need clarification before control station is installed. Resolution: No, the 9001KY enclosures have a bottom conduit opening standard. Extra conduit openings are not available.

Issue: Broke the white trip unit interlock behind the trip unit. Masterpact NW. NW breaker trips when it OPENS and red button pops out but no Ap light comes on. Does not trip when it closes. Product Line: Masterpact NW Environment: Masterpact NW Circuit Breaker Cause: Repair parts Resolution: Replace the trip unit base, part number 47947. This part is available only to Square D/Schneider Electric Field Services and they must do the installation.

Issue: Difference between a two types of two-speed starters Product Line: 8810 Multispeed Magnetic Starters Environment: NEMA Starters and Contactors Cause: Selecting a two speed starter Resolution: Multispeed motors are available in two basic versions: 1) separate winding and 2) consequent pole. A separate winding motor has a winding for each speed while a consequent pole motor has a winding for every two speeds (three-speed motors have two windings). The motor connections (and thus the types of controllers) for two speed starters are exemplified by the schematic diagrams shown in Table 16.22. Note that consequent pole two-speed controllers involve a 5-pole and a 3-pole starter, while separate winding controllers have two 3-pole starters. Verify the type of motor before ordering. Field modification of starters to match the motor may not be possible. Separate winding motors are usually chosen when flexibility is important, since the speeds of a consequent pole motor are usually limited to a 2/1 ratio; a broad range of speeds can be obtained on a separate winding motor. Both separate winding and consequent pole motors are available in three types: 1) constant horsepower, 2) constant torque, and 3) variable torque.

Issue: Where can I buy a Compact NSX breaker? Product Line: Circuit Breakers Cause: This breaker is popular overseas and there is interest in the US Resolution: There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated). If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number. For support on these breakers, Please see the following link to Global Operations where you can select other Countries: https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page