Clipsal Iconic Series 2 Architrave Switches - 10 A - Led - Vertical - Vivid White - 3042AL-VW

Clipsal Iconic Series 2 Architrave Switches - 10 A - Led - Vertical - Vivid White - 3042AL-VW

Rating:
100% of 100
Price
$26.26 $23.87
Dispatch. 2 days
3042AL-VW
Clipsal Iconic 3042Al-Vw 2 Architrave Switches - 10 A - Led - Vertical - Vivid White
LED
Clipsal Iconic Series 2 Architrave Switches - 10 A - Led - Vertical - Vivid White - 3042AL-VW
  • Clipsal Iconic Series 2 Architrave Switches - 10 A - Led - Vertical - Vivid White - 3042AL-VW
×
  • Clipsal Iconic Series 2 Architrave Switches - 10 A - Led - Vertical - Vivid White - 3042AL-VW
  1. Clipsal Iconic Series 2 Architrave Switches - 10 A - Led - Vertical - Vivid White - 3042AL-VW
Width 55
Height 48
Depth 149
Full Box -
Full Carton -
Full Pallet -

Specification
SKUCLI3042ALVW
RangeIconic Series
Length Packaging36
Height Packaging150
Depth Packaging50
Width55.000000
Height48.000000
Depth149.000000
BrandClipsal
Supplier No3042AL-VW
Current Rating10 Amps
ColourVivid White
Colour CodeVW
Number of Switches2
Mechanisms10 Amps
OrientationVertical
EAN / Barcode9311554785796
TypeArchitrave (type)
Speciality FeatureLED Indicator
LedYes

The Clipsal Iconic Flush Switch is an ideal solution for installations in tight spaces. Frequently used to fit the mouldings surrounding door frames, the smaller size of this flush-mount 2-way light switch makes it perfect when space is limited.

Customisable and future-ready

Iconic is based around a unique, electrically safe grid plate, with a choice of three different skin designs that simply clip on top.

Once the grids have been installed by an electrician, it’s safe for anyone to change the skins at any time. Simply clip off the standard skins and clip on the new design.

Interchangeable standard, Styl and Essence skins provide great options to customise to suit specific decor and lifestyle.

1 Reviews

FAQ

The plate dimensions are the same for 1 gang and 2 gang saturn architrave 97mm Hx 38mm W

The part number for a 2 gang Iconic switch plate and switch mech and dimmer is - 3042HA , 40M & 41E300PBUD2SM For further information , visit link below:- https://www.clipsal.com/Trade/search-results?q=3042HA https://www.clipsal.com/Trade/search-results?q=40M https://www.clipsal.com/Trade/search-results?q=41E300PBUD2SM

Issue: USF (undervoltage fault) on an ATV12 drive. Product Line: Altivar 12 Environment: All Cause: Fault condition Resolution: For N4, 480V drives at factory setting of 480VAC, the threshold is 430VDC on the DC bus or 304VAC on the line terminals. For M3, 240V drives at factory setting of 260VAC, the threshold is 230VDC on the DC bus or 163VAC on the line terminals. Recommendations: - Measure the the incoming line to line voltages - Compare the line voltage to the Mains Voltage as shown under monitoring MON. - If the standard line voltage is low, you can adjust the Mains voltage setting - Adjust the Undervoltage time out to compensate for line contactors, or add time delay before a fault would occur. - Check to issues where line potential is dropping due to supply issues that may be caused by load pulling too much current.

Issue: Causes of an USF fault on ATV61 drives. Product line: ATV61, ATV71, Altivar 61, Altuvar 71 Environment: All models Cause: Undervoltage supply. Resolution: The USF fault occurs when the DC bus voltage level drops below the threshold set in 1.8 Fault Management > Undervoltage Management > Undervoltage level. For N4, 480V drives at factory setting of 480VAC, the threshold is 430VDC on the DC bus or 304VAC on the line terminals. For M3, 240V drives at factory setting of 260VAC, the threshold is 230VDC on the DC bus or 163VAC on the line terminals. For Y, 575V drives at factory setting of 690VAC, the threshold is 571VAC on the DC bus, or 404VAC on the line terminals. Recommendations: - Measure the the incoming line to line voltages - Compare the line voltage to the Mains Voltage as shown under Menu 1.2 Monitoring, and also the measurement of the DC bus voltage. - If the standard line voltage is low, you can adjust the Mains voltage setting. - Adjust the Undervoltage time out to compensate for line contactors, or add time delay before a fault would occur.