Clipsal Iconic Series Switch - 10 A - Vertical - Ip44 - Vivid White - 3041V44-VW

Clipsal Iconic Series Switch - 10 A - Vertical - Ip44 - Vivid White - 3041V44-VW

Price
$39.39 $35.81
In Stock
3041V44-VW
Clipsal Iconic 3041V44-Vw Switch - 10 A - Vertical - Ip44 - Vivid White
Complete Product
Clipsal Iconic Series Switch - 10 A - Vertical - Ip44 - Vivid White - 3041V44-VW
  • Clipsal Iconic Series Switch - 10 A - Vertical - Ip44 - Vivid White - 3041V44-VW
×
  • Clipsal Iconic Series Switch - 10 A - Vertical - Ip44 - Vivid White - 3041V44-VW
  1. Clipsal Iconic Series Switch - 10 A - Vertical - Ip44 - Vivid White - 3041V44-VW
Width 78
Height 39
Depth 120
Full Box -
Full Carton -
Full Pallet -

Specification
SKUCLI3041V44VW
RangeIconic Series
Length Packaging120
Height Packaging39
Depth Packaging78
Width78.000000
Height39.000000
Depth120.000000
BrandClipsal
Supplier No3041V44-VW
Current Rating10 Amps
ColourVivid White
Colour CodeVW
Number of Switches1
Mechanisms10 Amps
OrientationVertical
EAN / Barcode9311554785710
Complete ProductYes

With an IP44 rating, the Clipsal Iconic Vertical 1 Gang switch is a good option for bathrooms and kitchens where some water spray might occur. Designed to be installed vertically, the 10AX, 250V switch is also rated for fluorescent and inductive loads as well as standard.

Customisable and future-ready

Iconic is based around a unique, electrically safe grid plate, with a choice of three different skin designs that simply clip on top.

Once the grids have been installed by an electrician, it’s safe for anyone to change the skins at any time. Simply clip off the standard skins and clip on the new design.

Interchangeable standard, Styl and Essence skins provide great options to customise to suit specific decor and lifestyle.

FAQ

Part number comes standard as Vivid White, will need Cool Grey cover to suit.

The part number for the 1 gang Iconic switch , and can the mech be rotated for horizontal or vertical switch plates - 3041VA and yes can be mounted Vertical or Horizontal.. For further information , visit link below:- https://www.clipsal.com/Trade/search-results?q=3041VA

3041/45, single pole 250V, 45A cooking appliance isolator can be vertical or horizontal mounted. However the mechanism orientation cannot be changed. For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=3041/45

Issue: Do we have any series ratings with the Masterpact NT and NW breakers? Product Line: Masterpact NW, NT Environment: Masterpact breakers in NEMA markets Resolution: There are no series ratings for Masterpact NT, NW circuit breakers. There are none for the obsolete SE or Masterpact MP either.

Issue: Transformer lug kits Product Line: LV Transformers Environment: Applies to Low Voltage Transformers by SquareD/Schneider Electric Cause: Transformers 15 KVA and over may require lug kits Resolution: Lug kits can be found in the online Catalog 7400CT0501. This kit includes 3 lugs per kit See attached.

Issue: Identifying trip point in a single phase sensitive overload relay Product Line: NEMA combination starters Environment: Products sold and used in the United States Cause: Identifying the trip point in a single phase sensitive Tesys D overload relay Resolution: The phase loss sensitive overloads are designed to conform to IEC standard 60947-4-1. In that standard is this paragraph: 8.2.1.5.2 Limits of operation of three-pole thermal overload relays energized on two poles With reference to table 4: The overload relay or starter shall be tested in its enclosure if normally fitted. With the relay energized on three poles, at A times the current setting, tripping shall not occur in less than 2 h, starting from the cold state, at the value of the ambient air temperature stated in table 4. (Table 4 `A` multiple of current setting states 2 poles at 1.0 times the current setting, the third pole at 0.9) Moreover, when the value of the current flowing in two poles (in phase loss sensitive relays, those carrying the higher current) is increased to B times the current setting, and the third pole de-energized, tripping shall occur in less than 2 h. (Table 4 `B` multiple of current setting is 2 poles at 1.15 current setting, third pole at 0.0.) The values shall apply to all combinations of poles. In the case of thermal overload relays having an adjustable current setting, the characteristics shall apply both when the relay is carrying the current associated with the maximum setting and when the relay is carrying the current associated with the minimum setting.