Clipsal Iconic Series Switch - 10 A - Vertical - Ip44 - Vivid White - 3041V44-VW
Clipsal Iconic Series Switch - 10 A - Vertical - Ip44 - Vivid White - 3041V44-VW
SKU | CLI3041V44VW |
---|---|
Range | Iconic Series |
Length Packaging | 120 |
Height Packaging | 39 |
Depth Packaging | 78 |
Width | 78.000000 |
Height | 39.000000 |
Depth | 120.000000 |
Brand | Clipsal |
Supplier No | 3041V44-VW |
Current Rating | 10 Amps |
Colour | Vivid White |
Colour Code | VW |
Number of Switches | 1 |
Mechanisms | 10 Amps |
Orientation | Vertical |
EAN / Barcode | 9311554785710 |
Complete Product | Yes |
Customisable and future-ready
Iconic is based around a unique, electrically safe grid plate, with a choice of three different skin designs that simply clip on top.
Once the grids have been installed by an electrician, it’s safe for anyone to change the skins at any time. Simply clip off the standard skins and clip on the new design.
Interchangeable standard, Styl and Essence skins provide great options to customise to suit specific decor and lifestyle.
FAQ
Part number comes standard as Vivid White, will need Cool Grey cover to suit.
The part number for the 1 gang Iconic switch , and can the mech be rotated for horizontal or vertical switch plates - 3041VA and yes can be mounted Vertical or Horizontal.. For further information , visit link below:- https://www.clipsal.com/Trade/search-results?q=3041VA
3041/45, single pole 250V, 45A cooking appliance isolator can be vertical or horizontal mounted. However the mechanism orientation cannot be changed. For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=3041/45
Issue: Do we have any series ratings with the Masterpact NT and NW breakers? Product Line: Masterpact NW, NT Environment: Masterpact breakers in NEMA markets Resolution: There are no series ratings for Masterpact NT, NW circuit breakers. There are none for the obsolete SE or Masterpact MP either.
Issue: Transformer lug kits Product Line: LV Transformers Environment: Applies to Low Voltage Transformers by SquareD/Schneider Electric Cause: Transformers 15 KVA and over may require lug kits Resolution: Lug kits can be found in the online Catalog 7400CT0501. This kit includes 3 lugs per kit See attached.
Issue: Identifying trip point in a single phase sensitive overload relay Product Line: NEMA combination starters Environment: Products sold and used in the United States Cause: Identifying the trip point in a single phase sensitive Tesys D overload relay Resolution: The phase loss sensitive overloads are designed to conform to IEC standard 60947-4-1. In that standard is this paragraph: 8.2.1.5.2 Limits of operation of three-pole thermal overload relays energized on two poles With reference to table 4: The overload relay or starter shall be tested in its enclosure if normally fitted. With the relay energized on three poles, at A times the current setting, tripping shall not occur in less than 2 h, starting from the cold state, at the value of the ambient air temperature stated in table 4. (Table 4 `A` multiple of current setting states 2 poles at 1.0 times the current setting, the third pole at 0.9) Moreover, when the value of the current flowing in two poles (in phase loss sensitive relays, those carrying the higher current) is increased to B times the current setting, and the third pole de-energized, tripping shall occur in less than 2 h. (Table 4 `B` multiple of current setting is 2 poles at 1.15 current setting, third pole at 0.0.) The values shall apply to all combinations of poles. In the case of thermal overload relays having an adjustable current setting, the characteristics shall apply both when the relay is carrying the current associated with the maximum setting and when the relay is carrying the current associated with the minimum setting.